Diagnostic Accuracy · AUC-2P
Sample Size for Comparing Two Paired AUCs
Plan sample size for comparing ROC AUCs when the same participants undergo two diagnostic tests.
4. Results
Enter the paired-AUC comparison assumptions and select Calculate.
Correlation sensitivity analysis
| rho | Total participants before inflation |
|---|
Suggested sample-size wording
Warnings
Formula, assumptions, limitations, and methodological note
Example clinical scenario
Every patient with suspected coronary disease undergoes two imaging tests, allowing their paired ROC AUCs to be compared against the same reference diagnosis.
Formula and methodological note
Design selection: Use this calculator only when both index tests are performed in the same participants. For separate participant samples, use the independent-AUC calculator.
Scope and limitations: Use this calculator only for the diagnostic design named on this page and its stated independent or paired sampling assumptions. It does not cover clustering, repeated lesions, multiple-reader designs, prediction-model development, or non-inferiority/equivalence unless explicitly stated. The implemented normal or binormal approximation may be unsuitable near parameter boundaries or with sparse reference-standard groups. Where prevalence is used, it supports recruitment planning and does not necessarily form part of the core precision or hypothesis-test calculation.
This calculator tests H0: AUC_A = AUC_B against H1: AUC_B = AUC_A + Delta for paired diagnostic tests performed in the same participants.
AUC_H0 = (AUC_A + AUC_B) / 2
a(x) = sqrt(2) x Phi^-1(x)
Balanced 1:1: V(x) = 0.0099 x exp[-a(x)^2 / 2] x [6a(x)^2 + 16]
D0 = 2 x V(AUC_H0) x (1 - rho)
D1 = V(AUC_A) + V(AUC_B) - 2 x rho x sqrt[V(AUC_A) x V(AUC_B)]
n = ceiling([Z alpha x sqrt(D0) + Z power x sqrt(D1)]^2 / Delta^2)
Consecutive/cross-sectional uses W(x, prevalence) = 0.0099 x exp[-a(x)^2 / 2] x [(5a(x)^2 + 8) / prevalence + (a(x)^2 + 8) / (1 - prevalence)]
D0_cross = 2 x W(AUC_H0, prevalence) x (1 - rho)
D1_cross = W(AUC_A, prevalence) + W(AUC_B, prevalence) - 2 x rho x sqrt[W(AUC_A, prevalence) x W(AUC_B, prevalence)]
N = ceiling([Z alpha x sqrt(D0_cross) + Z power x sqrt(D1_cross)]^2 / Delta^2)
Methodological note: This calculator is intended for superiority testing of two ROC AUCs from paired diagnostic tests performed in the same participants, with continuous or ordinal index-test results and a binary reference standard. It does not cover independent samples, non-inferiority or equivalence designs, clustering, repeated lesions, multiple readers, partial AUCs, or prediction models developed and evaluated in the same dataset.
Technical results
Method references
- Hajian-Tilaki K. Sample size estimation in diagnostic test studies of biomedical informatics. Journal of Biomedical Informatics. 2014;48:193-204. Eq. 7.6-7.9; Table 8.
Suggested citation
Yaacob, Najib Majdi. “Sample Size for Comparing Two Paired AUCs (AUC-2P).” Web calculator. NajibMY, 2026. Accessed July 29, 2026. https://najibmy.netlify.app/tools/sample-size/diagnostic-accuracy/two-paired-aucs/.